Sign In | Join Free | My chinalane.org |
|
Brand Name : Daruifuno
Model Number : P9.2
Certification : CE
Place of Origin : China
MOQ : Negotiable
Price : Negotiable
Product Name : Peracetic acid sensor water quality sonde
Product Model : Peracetic acid sensor P9.2
Measurand(s) : Peracetic acid
PH Range : 1 ~ 6pH
Pressure Range : 0 ~ 1bar
Response Time : T90 3.5 min at 10 °C, 45s at 50 °C
Flow Rate : 30L / h, low flow-dependence
Temperature Range : 0 ~ 60℃
Peracetic Acid Sensor 60℃ Water Quality Probe Tolerate Surfactants
Descriptions
The water quality probe peracetic acid sensor P9.2 is used for the measurement of peracetic acid C2H4O3, surfactants, and lead acids are tolerated. You can calibrate the sensor via analytical determination by DPD-method at the controller. The pH range of the peracetic acid probe is 1 ~ 6pH. The temperature range of the sensor is from 0℃ to 60 ℃. The material of the peracetic acid sensor is PEEK, stainless steel 1.4571.
About the interference: ClO2 increases the measuring value, H2O2 very low influence on the measuring value, reduces the PES signal, O3 increases the measuring value greatly.
Specifications
Product Name | Peracetic acid sensor water quality probe |
Product Model | Peracetic acid sensor P9.2 |
pH Range | 1 ~ 6 |
Pressure Range | 0 ~ 1bar, no pressure surges or fluctuations |
Temperature Range | 0~ 60℃ |
Response Time | T90 3.5 min at 10 °C,45 s at 50 °C |
Connection | For mA-version 2-pole terminal, M12 male or Modbus RTU with M12 male |
Shaft Length | Standard 175 mm, and up to 220 mm in length (mA-Version) |
Material | PEEK, stainless steel 1.4571 |
Flow Rate | 30 L/h, low flow-dependence |
Applications Of The Peracetic Acid Sensor
Freshwater, all types of water treatment.
Lead acids: up to 1% sulfur, saltpeter, and phosphoric acid have no influence on the measuring results.
Surfactants are tolerated.
Scope Of Supply
Water quality probe peracetic acid sensor P9.2: sensor, membrane cap, electrolyte.
Ordering Data:
Type | Measuring range(ppm) | Resolution(ppm) | Output signal | Power supply | Item number |
P9.2H-M0c | 0.0 ~ 200.0 | 0.1 | Modbus RTU | 9 ~ 30 V DC | 3426130 |
P9.2N-M0c | 0 ~ 2000 | 1 | 3426131 | ||
P9.2L-M0c | 0 ~ 2 % (20000) | 0.001 % (10) | 3426132 | ||
P9.2-MA-200 | 0.0 ~ 200.0 | 0.1 | 4 ~ 20mA | 12 ~ 30 VDC RL 50 ~ 900Ω | 3426100 |
P9.2-MA-2000 | 0 ~ 2000 | 1 | 3426101 | ||
P9.2-MA-2% | 0 ~ 2 % (20000) | 0.001 % (10) | 3426102 | ||
P9.2-MA-200-M12 | 0.0 ~ 200.0 | 0.1 | 4 ~ 20mA | 12 ~ 30 VDC RL 50 ~ 900Ω | 3426100 |
P9.2-MA-2000-M12 | 0 ~ 2000 | 1 | 3426101 | ||
P9.2-MA-2%-M12 | 0 ~ 2 % (20000) | 0.001 % (10) | 3426102 |
If you are interested in the water quality probe peracetic acid sensor P9.2, please contact us.
![]() |
Peracetic Acid Sensor 60℃ Water Quality Probe Tolerate Surfactants Images |